Info |
---|
This article provides details about errors with SNMP values that result in increased usage percentages. |
Status |
---|
colour | Blue |
---|
title | Applicable to all Checkmk versions |
---|
|
Panel |
---|
borderColor | black |
---|
bgColor | #f8f8f8 |
---|
title | Table of Contents |
---|
|
|
Problem
A POE-enabled network interface shows ridiculously high an excessive usage percentage.
e.g. POE usage (32000W6000W/1800W): : 1777% 333% (warn/crit at 90.0%/95.0%)
Reason
Some hardware vendors violate the SNMP RFC and output milliwatts instead of watts for pethMainPseConsumptionPower
.
Image Added
When looking at an SNMP walk of the affected device, it will become evident that the value in pethMainPseConsumptionPower (1.3.6.1.2.1.105.1.3.1.1.4.1)
is not output in watts:
Code Block |
---|
language | bash |
---|
theme | Midnight |
---|
|
OMD[mysite]:~$ grep .1.3.6.1.2.1.105.1.3.1.1. ~/var/check_mk/snmpwalks/my_device
.1.3.6.1.2.1.105.1.3.1.1.2.1 1800
.1.3.6.1.2.1.105.1.3.1.1.3.1 1
.1.3.6.1.2.1.105.1.3.1.1.4.1 6000 |
Checkmk then uses these values to calculate the percentages:
Code Block |
---|
language | bash |
---|
theme | Midnight |
---|
|
6000/1800 → 333% |
Those are then wrong, of course, because if your input data is faulty, the result of your calculation will also be faulty.
Solution
As the bug lies within the SNMP implementation of the affected device, the hardware vendor needs to must fix this bug in the firmware.
Please open a ticket with the vendor and ask them to fix the bug.