Info

This article explains an integer overflow error that can happen while converting TimeTicks.

Status
colourGreen
titleLAST TESTED ON CHECKMK 2.3.0P1


Panel
borderColorblack
bgColor#f8f8f8
titleTable of Contents

Table of Contents

Problem

SNMP traps cannot be processed. While An Integer overflow occurs while converting TimeTicks (in this case  case, the "time-stamp" of an snmpv1 trap) an Integer overflow occurs.

This message is from the mkeventd.log with debug enabled (Setup → Events → Event Console  → Settings → Event Console: Logging & diagnose → Log level → Processing of incoming events: Debug)

Code Block
languagebash
themeRDark
2020-12-10 13:35:49,501 [10]
[cmk.mkeventd.EventServer.snmp] receiveMessage: <ConstraintsIntersection object at 0x7fb225b324d0 consts <ValueRangeConstraint object at 0x7fb225b32410 consts 0, 4294967295>> failed at: ValueConstraintError('<ValueRangeConstraint object at 0x7fb225b32410
consts 0, 4294967295> failed at: ValueConstraintError(-1935586285,)',) at TimeTicks


Solution

...

Note

This looks

...

like a

...

relatively common bug in SNMP devices when they try to encode large positive numbers

...

; we have already seen this for "Counter" values, and this time it's "TimeTicks."

...


  • The relevant part from the SNMP-RFCs 

...

  • RFC 1155 and RFC 1902 are:

    Code Block
    languagebash
    themeRDark
    TimeTicks ::=
        [APPLICATION 3]
            IMPLICIT INTEGER (0..4294967295)

    .

  • INTEGER in ASN.1

...

  • is 

...

  • always signed, so when doing the BER encoding of such a value, one

...

  • must add a leading zero for large numbers,

...

  • otherwise

...

  • interpreted as negative (2's complement). This is exactly what the faulty device doesn't do. If one likes to play around with such things a bit, there

...

...

  • ; it seems to try to "fix" the value. One can do this by hand, BTW: -471450490 + 2^32 = 3823516806, which are the values we see above. This "fixing" is, in fact, incorrect

...

  • ; I guess it's

...

  • tcpdump trying to be nice

...

  • to the reader.

  • The decoding on the Checkmk side is done by a rather standard library, which

...

  • behaves in a totally correct way, so there is not

...

  • much

...

  • that can be done on our side.

In a nutshell: Contact the manufacturer of your device

...

; perhaps there is a firmware update or something like that

...

that fixes their bug.