Problem

If you receive notifications regarding critical SSD temperatures, it's important to note that the Checkmk software utilizes standard threshold values of 0-40°C when the disks do not provide specific thresholds. However, these values may not align with the manufacturer's specifications. Therefore, it is recommended to adjust the temperature thresholds in Checkmk to match the specifications provided by the manufacturer for accurate monitoring and alerting.


Screenshot of Smart sensor on SSD reading Crit

Screenshot of further details about the temp sensor and it reading Critical after reaching 51 Celsius

Solution

Before making any adjustments, it is advisable to consult the manufacturer of your SSD to determine the recommended operating temperature range. In this example, we use a Micron SSD ranging between 0-70°C.

...

By customizing the temperature levels based on the manufacturer's specifications, you can ensure accurate monitoring and receive notifications aligned with the recommended operational temperatures for your SSD.