Problem

If you receive notifications regarding critical SSD temperatures, it's important to note that the Checkmk software utilizes standard threshold values of 0-40°C when the disks do not provide specific thresholds. However, these values may not align with the manufacturer's specifications. Therefore, it is recommended to adjust the temperature thresholds in Checkmk to match the specifications provided by the manufacturer for accurate monitoring and alerting.


Screenshot of Smart sensor on SSD reading CritImage Modified

Screenshot of further details about the temp sensor and it reading Critical after reaching 51 Celsius Image Modified

Solution

Before making any adjustments, it is advisable to consult the manufacturer of your SSD to determine the recommended operating temperature range. In this example, we use a Micron SSD ranging between 0-70°C.


Screenshot of the manufactures recommendation on temperature levels.  Here it shows acceptable levels are between 0-70 Celsius. Image Modified


  1. To adjust these thresholds, click on the hamburger menu and then "Parameters for this Service."
    Screenshot of clicking the hamburger menu and selecting Parameters for this service.Image Modified
    .
  2. You will now want to click on "Temperature."
    Screenshot of the location of the temperature option.Image Modified
    .
  3. Click "Add Rule"
    Screenshot of clicking Add RuleImage Modified
    .
  4. Place an [X] in the Upper and Lower Temperature Level boxes to enable custom threshold values. Set the desired Warning and Critical levels for both. 
    Screenshot of new rule and new thresholds set per the manufactures recommendation. Image Modified
    .
  5. Save the new configuration and activate the changes.

By customizing the temperature levels based on the manufacturer's specifications, you can ensure accurate monitoring and receive notifications aligned with the recommended operational temperatures for your SSD.